Unit 8. Lab 1. Fiber Optic Connector Assembly

622 words - 3 pages

Unit 8. Lab 1. Fiber Optic Connector Assembly
The most critical part, the Cable and Fiber Preparation where the fiber is mounted, is the ferrule. The Ferrule is a long, thin cylinder with the fiber mounted in the center hole. The center hole is sized to match fiber's cladding diameter which is usually 125um. When fiber connector ferrules are made from several types of materials including ceramic(Zirconia), stainless steel and plastic. The ferrule's job is to center and align the fiber and protects it from mechanical damage. The end of fiber is at the end of the ferrule, where the fiber end is polished smooth either flat or with a curvature. The ferrule is mounted in the connector body and then the connector body is attached to the fiber optic cable structure. Finally, a strain-relief rubber boot protects the connector-cable junction.
Fiber optic connectors usually do not have the male-female ...view middle of the document...

The fiber's plastic coating is stripped first before the fiber is inserted in the ferrule. The center hole through the ferrule is large enough to fit the

Fiber cladding (which is usually 125um after fiber coating stripped off) but tight enough to hold the fiber in a fixed position without any further moving.
Standard bore diameters are 126 +1/-0 um for single mode connectors and 127 +2/-0 um for multimode connectors. Because of fiber cladding diameter's variation from manufacturing, some fiber connector manufacturers also supply a range of ferrule bore sizes such as 124um, 125um, 126um and 127um. Fiber optic epoxy or adhesive is injected into the ferrule hole before the fiber is pushed in to hold the fiber in place. The epoxy or adhesive is then cured with high temperature oven according to adhesive manufacturers' instruction. Finally the fiber end is polished to a smooth face on polishing films.
The ferrule is slipped inside another hollow cylinder before it is mounted in the connector body. The connector body includes one or more pieces that are assembled to hold the cable and fiber in place. Connector body is made of metal or plastic. The ferrule end protrudes beyond the connector body so it can slip into the mating sleeves (fiber adapters). A stain-relief rubber boot is finally slipped over the cable end of the connector to protect the cable-connector junction point. In fiber optic cross connect boxes or fiber patch panels, an array of connector adaptors are mounted inside, ready for you to plug an input fiber cable in one side and an output cable in the other. Fiber connector adapters are also mounted in wall outlets, just like standard phone jacket.
I think polishing the fiber is the last and very critical step in the connectorization process. Polishing finalizes the connector end face and cleans the surface, which has a direct impact on such optical performance parameters as insertion loss, return loss, and bit-error-rate for overall network performance. Reliable polishing processes rely on proper training and a well-equipped termination toolkit.

Other Papers Like Unit 8. Lab 1. Fiber Optic Connector Assembly

Unit 3: Lab 1: Building a New Structure - Nfpa Codes

1415 words - 6 pages Unit 3: Lab 1: Building a New Structure – NFPA Codes The transmission of words, sounds, images, or data in the form of electronic or electromagnetic signals or impulses: Telecommunications what a concept. In order for us as a person and an IT Administrator is to stay safe. History has shown the safety departments about having to write policies which are used to provide recommended practices for the design and installation of safety standards

Unit 7. Lab 1. New Building – Safety Plan

1431 words - 6 pages Unit 7. Lab 1. New Building – Safety Plan Making safety a priority may be as simple as sending a letter to all employees outlining your plans to make safety as important as quality. Your employees should believe just as strongly as you do in safety. Hire the safest employees, starting in the interview process. Get a sense of how prospective employees feel about a total commitment to safely. Have they worked in other organizations where safety

Unit 5 Lab 1

1058 words - 5 pages Wired and Wireless Networks ITT Technical Institute Physical Networking – NT1310 11/10/2014 Wired and Wireless Networks The biggest difference between these two types of networks is one uses network cables and one uses radio frequencies. A wired network allows for a faster and more secure connection and can only be used for distances shorter than 2,000 feet. Several other disadvantage of a wired network such as the “need to run cables in

Nt1130 Unit 1 Lab

357 words - 2 pages Unit 1 Assignment 1: Windows 2008 Network Services Most networks out there will take advantage of DNS and DHCP services. These services make managing a network an easier task for the administrator. While they are not always required for a network to function, most cases they will be used. Knowing what these services do will help the administrator determine if they are required for the network. DNS stands for Domain Name System. What this

Unit 8 Lab 6: Control Panel Exercises

547 words - 3 pages 1) Computer differentness Dell-inspiron desk top | HP-pavilion HPE desk top | Model : 1660s-2000Bk | Model : H8-1234 | Hard disk capacities | 500GB | Hard disk capacities | 1TB | Amount of ram/expandable ram | 4GB/8GB | Amount of ram/expandable ram | 10GB/36GB | Processor speed | 2.7 Ghz | Processor speed | 3.56 Ghz | Cost | $399.99 | Cost | $699.99 | Toshiba -Satellite laptop | HP-Elite Book Laptop | C855D-S5205 | Model

Nt1310 Unit 2 Lab 1

1403 words - 6 pages Amazon With amazon services you choose a service plan based upon a completely virtual environment. Using a preconfigured AMI (amazon machine image) or creating your own with its own set of network permissions and protocols. This also chooses instance types you may want. Multiple services using AMI and with that utilize static endpoints or attach persistent block storage to said instances. The resources you use is what you will pay for out of the

Is 3120 Unit 1 Lab 1

324 words - 2 pages Use the internet to help you answer the following questions: 1. What is the current state of IPv6? Estimate what percentage of the network infrastructure is running IPv6 traffic. What percentage of the network is running IPv4 traffic? IPv6 - Reports in November 2008, indicated that penetration was still less than one percent of Internet traffic in any country. The leaders were Russia (0.76%), France (0.65%), Ukraine (0.64%), Norway (0.49

Health Science Unit 1 Lab Questions

792 words - 4 pages 1.What are some of the advantages and disadvantages of the current health care system in the United States? Some disadvantages of the current health care system in the United States is tons of people have no healthcare insurance at all and many of the insurance coverages have such high premium and deductibles people can't afford it. For you to be eligible for Medicaid you have to have a very low income. To get Medicare you have to be a

Nt1310 Week 4 Assignment

1433 words - 6 pages identification. The telecom installation drop-light is light weight and compact unit is ideal for use while installing copper and fiber connectors in those hard to reach areas in and around equipment racks, cabinets and frames. Cable pulling lubricant: for pulling inner duct, communications, coaxial and fiber optic cables. It is always good to follow the rules below when working with fiber: 1. Dispose of all scraps properly. 2. Always use a

Cabling Definitions

1158 words - 5 pages signal. Fiber-optic cables are desirable in environments that have high EMI because they are not susceptible to the effects of EMI. 19. Optical-Fiber Strand-An optical fiber is a flexible, transparent strand of very pure glass that acts as a light pipe to transmit light between two ends of the fiber. 20. Index of Refraction-(1) The ratio of the speed of light in a vacuum to the speed of light in a given transmission medium. This is usually

Nt 1310 Midterm Exam Review

691 words - 3 pages 1. Plenum and coaxial cable are not common cables used today. 2. A decibel is the unit of measurement that is a tenfold logarithmic ratio of power output to power input. 3. Frequency increases does not contribute to attenuation. 4. Mutual crosstalk is not a type of crosstalk. 5. The Federal Communications Commission (FCC) is part of the US government. 6. The National Fire Protection Association (NFPA) is responsible for the

Related Essays

Nt1310 Unit 8 Lab Essay

2112 words - 9 pages Give a basic explanation of each step necessary to assemble a connector to a piece of fiber optic cable 1. Cable and Optical fiber preparation 2. Oven cured Epoxy application and connector assembly 3. Oven cured epoxy polishing General Guidelines The following contains information on the placement of fiber optic cables in various indoor and outdoor environments. In general, fiber optic cable can be installed with many of the same

Is3440 Unit 1 Lab Assessment Sheet

503 words - 3 pages were (or were not) running. Lab Assessment Questions & Answers 1. During the Minimal install, NTP (Network Time Protocol) server was not installed. From a security perspective, why is it important for a system to keep accurate time? To keep the system in sync and up to date for logging purposes such as any incidents that occur. Otherwise a time may not be correct when checking logs for an incident. 2. During the install, you set a

Unit 8 Assignment: 1 Written Reflection On Our Interview

329 words - 2 pages Unit 8 Assignment:1 Written Reflection on Our Interview After conducting my interview, I can say that I walked away from this experience with many a lesson learned. The first lesson that I learned was that after choosing a person to interview, then asking that person, most will jump on the defensive and ask “about what”. This is due to the fact that most people are usually pressed for time. They initially want to know how

Unit 1 Lab 1 Essay

1456 words - 6 pages Exercise 1.1.1 293110 103 102 101 100 1000 100 10 1 2 9 3 1 2000 900 30 1 Exercise 1.1.2 1102 27 26 25 24 23 22 21 20 128 64 32 16 8 4 2 1 0 0 0 0 0 1 1 0 0 + 0 + 0 + 0 + 0 +4 + 2 + 0 = 6 Exercise 1.1.3 112 27 26 25 24 23 22 21 20 128 64 32 16 8 4 2 1 0 0 0 0 0 0 1 1 0 + 0 + 0 + 0 + 0 + 0 + 2 + 1 = 3 Exercise 1.1.4 100102 27 26 25 24 23 22 21